Accident handling of glass lined reactor
The reaction materials added to the glass lined reactor are mostly high-temperature, high-pressure, flammable and explosive media. If improper operation or equipment leakage occurs, it will cause incalculable losses. For the correct use of the reactor and emergency handling We must pay attention to it. Here are some ways to deal with accidents:
1. If overpressure occurs, immediately open the vent valve to relieve the pressure.
2. If the glass lined reactor is over-temperature, immediately use water to cool down, but do not use too low temperature water for cooling. The temperature after cooling meets the process requirements.
3. If there is a power failure or a power failure during feeding, immediately stop feeding and open the vent valve. For long-term shutdown, the remaining liquid in the kettle should be cleaned and cleaned, and the feed valve, steam inlet valve, bottom valve and discharge valve should be closed.
4. The condensate discharge is blocked and the reactor is severely deformed. Emergency measures shall be taken to discharge the condensate. If it is still invalid, emergency measures shall be taken to stop the reaction.
The above are the emergency treatment methods for several accidents in the use of glass lined reactors. Of course, the more important thing is to prepare ingredients and feed materials in accordance with the process regulations, improve equipment management rules and regulations, and do a good job of pre-job training for operators to take precautions.